Difference between revisions of "Diyspotwelder"

From Technologia Incognita
Jump to: navigation, search
(Created page with "{{Project |ProjectSkills=Electronics, Metal- and woodworking, Soldering electronics programming, |ProjectStatus=Planning |ProjectNiche=Mechanics |ProjectPurpose=Infrastructur...")
 
Line 1: Line 1:
 
{{Project
 
{{Project
|ProjectSkills=Electronics, Metal- and woodworking, Soldering electronics programming,  
+
|ProjectSkills=Electronics, Metal- and woodworking, Soldering electronics programming,
 
|ProjectStatus=Planning
 
|ProjectStatus=Planning
 
|ProjectNiche=Mechanics
 
|ProjectNiche=Mechanics
Line 15: Line 15:
  
 
The plan:
 
The plan:
1 Start with a simple test-setup to check if everything works like it should
+
* Start with a simple test-setup to check if everything works like it should
2 Add proper welding-terminals and enclosure
+
* Add proper welding-terminals and enclosure
3 Make an assembly with spring-loaded clamping system
+
* Make an assembly with spring-loaded clamping system
4 Add timing and/or power-control to it
+
* Add timing and/or power-control to it
5 Add a foot-pedal system to it to allow two-hand operation
+
* Add a foot-pedal system to it to allow two-hand operation

Revision as of 15:26, 14 August 2014

Projects
Participants
Skills Electronics, Metal- and woodworking, Soldering electronics programming
Status Planning
Niche Mechanics
Purpose Infrastructure

Lately, hackaday et al. have been supplying a number of reviews/buildlogs of DIY spotwelders. They all seem to be based around taking a used/surplus microwave transformer and removing the secondary (highvoltage) core , replacing it with a few turns of thick copper-cable which instead take the power from the primary coil and turns it into low-voltage, high-power.

Current state: We've liberated a transformer from a microwave; removed the secondary coil with a hacksaw. Saved the 'shunts'. It's now stored on a shelf below the 'woodworking-tables', next to the 'printer parts box'.

Meanwhile, Justa has found a nice two-conduit cable, used for supplying -48V power to telco-equipment. They contain 2 conductors, both consisting of 5-6 solid-core copper wires normally used to supply 20A+ each. Total cable-length is around 2meters, supplying up to 4 meters of heavy-duty copper-cable, useful for secondary coil. On one side, the copper cable has been finished with a galvanized-metal ring-lug; possibly to be replaced with a set of 'copper offset clamps' which seem perfect for the job.


The plan:

  • Start with a simple test-setup to check if everything works like it should
  • Add proper welding-terminals and enclosure
  • Make an assembly with spring-loaded clamping system
  • Add timing and/or power-control to it
  • Add a foot-pedal system to it to allow two-hand operation